D*AP8
84
Setup GUI – EVENTS – Actions – Bypass Actions
The bypass action is bound to the <BYPASS> button of the X*AP RM
1
remote panel.
You must simply select "follow" or "-" in the setup field.
But it also allows you to turn the bypass on for, some or all function blocks by simply enabling the check
boxes in the right hand panel:
Triggered Bypass
Trigger
Source The X*AP RM1 <BYPASS> button is the trigger source
Lock Source [ON / OFF]
The X*AP RM
1
remote panel <BYPASS> button may be
disabled / enabled here.
Force Trigger Active [ON / OFF]
Force the bypass function from the GUI instead of the
X*AP RM
1
remote panel <BYPASS> button.
Bypass Event [4 x 2 / 5.1 + 2]
Programs [Input / Upmix / Filter – Spectral Signature / Filter – Equalizer /
Dynamics – Compressor / Voice Over / Level Magic – Leveler /
Level Magic –Limiter / Output]
AUX [Input]
Manual Bypass You can use the check boxes for manually bypassing the respective
function block of that program.